OPERATING AND USER MANUAL OPAL FAMILY
76
OPTION: AEC/VEM
Defining VEM behavior
10.5.1.
Six advanced parameters, defining VEM behavior can be set and read back by means of the VEMP
command. Refer to table below for a description of these parameters and their default values.
Command syntax:
VEMPx;y
Where
x = advanced parameter
y = advanced parameter value
Command syntax:
VEMP?x
Reply: y
Where x and y as above
x
range of the setting
parameter value description
0
1 .. 255
Control Speed factor. High factor is fast response
1
0, 1
0 VEM active on complete window (ROI)
1 VEM active on VEM window only
2
1 .. 12799
VEM maximum AGC gain in units of 0.01
3
1 .. 12799
VEM maximum contrast gain budget in units of 0.01
4
1 .. 12799
VEM maximum contrast Gain in units of 0.01
5
0 .. 9
VEM softness factor minimum detection
6*
0 ..4095
The current mean detection value used by the VEM in
12 bit video resolution
7*
0 ..4095
The current minimum detection value used by the VEM
in 12 bit video resolution.
8*
0 ..4095
The current gain value used by the VEM
9*
-4095 .. 0
The current black level value used by the VEM
*read only
Range of the VEM settings
Table 10.2:
Summary of Contents for Camera Link OPAL Series
Page 1: ...Operating and user manual OPAL FAMILY CAMERA LINK MODELS ...
Page 2: ...OPERATING AND USER MANUAL OPAL FAMILY 2 ...
Page 9: ...OPERATING AND USER MANUAL OPAL FAMILY 9 ...
Page 10: ...OPERATING AND USER MANUAL OPAL FAMILY 10 ...
Page 14: ...OPERATING AND USER MANUAL OPAL FAMILY 14 SAFETY INFORMATION ...
Page 22: ...OPERATING AND USER MANUAL OPAL FAMILY 22 ...
Page 30: ...OPERATING AND USER MANUAL OPAL FAMILY 30 ...
Page 34: ...OPERATING AND USER MANUAL OPAL FAMILY 34 ...
Page 86: ...OPERATING AND USER MANUAL OPAL FAMILY 86 REVISION HISTORY ...