OPERATING AND USER MANUAL OPAL-FAMILY
84
REFERENCE
COMMAND
DESCRIPTION
RQ
Generates soft request event
RQSIZE
Sets the number of images to release from burst memory
RQSIZE?
Gets the number of images to release from burst memory
SC
Saves the current configuration, settings 0 cannot be saved by an user.
SN?
Gets the camera serial number.
TM?
Gets the actual temperature of the sensor.
TP
Selects display of the test pattern
TP?
Gets the current test pattern display status
USI
Stores an integer in the camera.
USI?
Retrieves an integer from the camera.
USS
Stores a string in the camera.
USS?
Retrieves a string from the camera.
VBIN
Sets the vertical binning
VBIN?
Retrieves the image output binning
VR?
Sets vertical remap function for camera link
VS?
Gets current sensor substrate voltages
WB
Sets the gain for the Red, Green and Blue channel (Color only)
WB?
Gets the gain for the Red, Green and Blue channel (Color only)
Command set table
Table 11.7:
Factory Default settings (power-up set 0)
11.6
COMMAND
RANGE
DEFAULT
BL
0..4095
20
CCE
0..4;0..1
0;0
CCFS
0..5;0..1
0;0
DPE
0..1
1
FP
0..32000
different for each camera model.
FSE
0..1
0
FSM
0..1
0
FSP
0..1
0
FST
0..32000; 1..32000
0;1
GA
100..3200
100
IT
1..32000
different for each camera model.
MI
0..3
0
MO
0..3
0
OFS
0..4095
20
OR
8, 10, 12
12
OVL
0..1
0
TP
0..1
0
VBIN
0..1 (0..3 optional)
0
VR
0..1
0
WB
100..399; 100..399; 100..399
100; 100; 100
VR
0..1
0
Summary of Contents for Camera Link OPAL Series
Page 1: ...Operating and user manual OPAL FAMILY CAMERA LINK MODELS ...
Page 2: ...OPERATING AND USER MANUAL OPAL FAMILY 2 ...
Page 9: ...OPERATING AND USER MANUAL OPAL FAMILY 9 ...
Page 10: ...OPERATING AND USER MANUAL OPAL FAMILY 10 ...
Page 14: ...OPERATING AND USER MANUAL OPAL FAMILY 14 SAFETY INFORMATION ...
Page 22: ...OPERATING AND USER MANUAL OPAL FAMILY 22 ...
Page 30: ...OPERATING AND USER MANUAL OPAL FAMILY 30 ...
Page 34: ...OPERATING AND USER MANUAL OPAL FAMILY 34 ...
Page 86: ...OPERATING AND USER MANUAL OPAL FAMILY 86 REVISION HISTORY ...