OPTION: AEC/VEM
Controlling the AEC setpoint and VEM measurement window
10.5
Setpoint and window can be altered with the AECSP (setpoint) and ARCWIN (window) commands
respectively
Command syntax:
AECSPx
Where
x= 0 .. 4095
NOTE:
x= 0 : setpoint at absolute black
x= 1024: setpoint at 1/4 x Full Scale
x= 4095: setpoint at Full Scale
Command syntax:
AECSP?
Reply: x
Where x: as above
Command syntax:
VEMWINx;y;w;h
Where
x = 0 .. left side of window/HBIN factor
y = 0 .. top of window/VBIN factor
w= 2 .. width of window/HBIN factor
h= 2 .. height of window/VBIN factor
Command syntax:
VEMWIN?
Reply: x;y;w;h
Where x, y, w and h as above