![ADEMCO VIDEO RapidView Operation Manual Download Page 53](http://html1.mh-extra.com/html/ademco-video/rapidview/rapidview_operation-manual_3047325053.webp)
Rapid View Operation Guide
Page 47 © Ademco Video 2002 MNRDVO250602US
Chapter 5
Figure xx. Once positioned at the RLHS, press the ‘AUX’ button to set
this position.
Note:
NOTE: The camera should be panned in clockwise
direction, as viewed from the monitor, and in a direc-
tion away from the LHS. If the camera is moved in
an anti-clockwise direction, towards the LHS, then
you will create one big Sector Zone.
Figure xx Defining a Sector Zone
Each of the sixteen Sector Zones has a priority, Sector Zone 1 has the
highest priority and Sector Zone *16 has the lowest Priority. If any
Sector Zones overlap, then where the overlap occurs the higher
priority Sector Zone will be displayed.
Once positioned at the RHS, press the ‘AUX’ button to set this
position.
13.2
Editing the Sector Zone Label
For details on editing the Sector Zone Label, refer to section 4.0 earlier
in this chapter.
SECTOR ZONE 1
Set LHS (start of
Sector Zone)
Pan clockwise ( size
of Sector Zone)
Set RHS (end of
Sector Zone)
Summary of Contents for RapidView