Figure x Remote Reset (Power-up Reset) Menu
A camera number can be entered then the ’CAMERA’ button
pressed. The RapidView will then switch to that
camera, providing that the camera input is available. This
enables you to view the camera that you want to reset.
For this feature to function correctly there must be a video
signal at the camera input of the RapidView
To check that a particular camera is present, do the following:
Enter a valid camera number using the ’NUMBER’ keys, then
press the ’CAMERA’ key to select it. If no video signal is
present then the camera number will go to the next camera that
has a valid video signal.
If you know that a camera is on a particular video input, but no
picture is being displayed, then you can still reset the camera.
To select a particular camera that you know is present, but is
not displaying a video picture, do the following:
Enter a valid camera number using the ’NUMBER’ keys, then,
using the joystick, move down to the options field, i.e. where
the option ’POWER-UP RESET’ will be flashing as shown
overleaf.
R E M O T E
R E S E T
C A M E R A
0 5
P O W E R -
U P
R E S E T
C A M E R A
T O
S E L E C T
L O C K
T O
E N D