Chapter 5 - Monitoring and Testing the Campus System
Campus-REX2 RS Interface Card User Manual
89
R
ESETTING
THE
C
AMPUS
U
NIT
You can issue a reset for the Campus unit which causes it to complete a soft
reboot. Use this function when one of the following occurs:
•
The Port LED flashes green and the
REX2 Module Not Read
y message
is displayed when trying to access the REX2 interface. This indicates that
the Campus desktop or line unit is not communicating with the REX2
card for more than 1 minute after power-up was indicated.
•
HDSL, REX2, or system configuration changes have been made, but not
saved, and you want to revert to the previously saved configuration.
•
The REX2 is not functioning properly as indicated by excessive LAN
errors or
Not available
displayed for configuration values.
During the reset, the Port and HDSL LEDs on the desktop unit flash.
It is not required that you reset the REX2 after a configuration change or
when you complete a save function.
1
From the Main Menu, type
then press
.
4
ENTER
Jul 07, 2003
ADC TELECOMMUNICATIONS, CAMPUS RS, Version 5.1 08:19:34
Local Unit ID:
Southall Quad 4
Local I/F:
REX2
Remote Unit ID: Inactive
Remote I/F: Inactive
Circuit ID:
Southeast line 421
MAIN MENU
1)
SYSTEM STATUS
2)
REX2 CONFIGURATION AND STATUS
3)
SYSTEM CONFIGURATION
4)
MAINTENANCE
5)
REMOTE LOGON
(L)ogout
ENTER CHOICE>
Summary of Contents for Campus-REX2 RS
Page 1: ...CAMPUS REX2 RS INTERFACE CARD VERSION 5 1 USER MANUAL...
Page 12: ...Table of Contents xii Campus REX2 RS Interface Card User Manual...
Page 30: ...Chapter 1 Installing and Accessing the REX2 18 Campus REX2 RS Interface Card User Manual...
Page 76: ...Chapter 3 Configuring the REX2 64 Campus REX2 RS Interface Card User Manual...
Page 108: ...Chapter 6 Managing Software 96 Campus REX2 RS Interface Card User Manual...
Page 164: ...Index 152 Campus REX2 RS Interface Card User Manual...
Page 165: ......