5.9.4 Command Memory
When current in the series circuit is lost if a CCR is turned off or for any other reason, RELIANCE IQ remembers the current
lamp status for a limited amount of time. The IQ can be configured to, once current is restored in the circuit, set the lamp to
the remembered state, typically the last commanded state before a power loss. This feature, when enabled, overrides the
default state.
It is possible to apply a condition based on the amount of time current was lost. The RELIANCE IQ sets the lamp to default
state if current was restored beyond this time limit. The time limit is programmable from approximately 1-20 seconds.
5.9.5 Soft ON/OFF
The RELIANCE IQ can be programmed to delay the physical turn on or turn off of the lamp upon reception of a command
from the SCM. The feature is called SoftON / SoftOFF and its purpose is to mitigate the sudden load change to which the CCR
is subjected when a large portion of the load is commanded on or off with a single command. The command acknowledge
from the RELIANCE IQ is not affected, and thereby neither the response time. Without this feature it may not be possible to
turn on or off all or most lights on a circuit with a single command without the CCR tripping either because of over- or under-
current.
The physical delay is programmable on an individual level in 10ms increments. There is no response time impact when
SoftON / SoftOFF is enabled.
5.9.6 Sequenced Flashing
RELIANCE IQ can be used to create different types of “running rabbit” patterns on the series circuit.
UM-5027, Rev. 1.0, 2020/12/10
25
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE
Page 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Page 2: ......
Page 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Page 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Page 76: ......