6. Looking from above, make sure the prism edge is parallel with the prism holder, see
Figure 25: Prism holder edge
7. Use alcohol based cleaner to remove any grease or dust from the prism.
8. Attach the LED board holder, including screws. The screws on the LED holder shall be tightened to a torque of 4.5 Nm, in
sequence 1-4. Tighten the same screws again to a torque of 4.5 Nm, in sequence 5-8. See
.
Note
The torquing sequence must be respected as it ensures correct positioning of the prism.
Figure 26: Tighten screws in sequence
1 5
3 6
4 7 2 8
9. Re-tighten the two screws on the steel plate to 4.5 Nm. See
10. Assemble the light fixture.
UM-5027, Rev. 1.0, 2020/12/10
47
Copyright
©
ADB SAFEGATE, All Rights Reserved
Summary of Contents for RELIANCE
Page 1: ...RELIANCE Omni Light 8 inch User Manual UM 5027 Rev 1 0 2020 12 10 ...
Page 2: ......
Page 8: ...RELIANCE Omni Light List of Figures viii Copyright ADB SAFEGATE All Rights Reserved ...
Page 10: ...RELIANCE Omni Light List of Tables x Copyright ADB SAFEGATE All Rights Reserved ...
Page 22: ...RELIANCE Omni Light General Information 12 Copyright ADB SAFEGATE All Rights Reserved ...
Page 26: ...RELIANCE Omni Light Installation 16 Copyright ADB SAFEGATE All Rights Reserved ...
Page 36: ...RELIANCE Omni Light Operation 26 Copyright ADB SAFEGATE All Rights Reserved ...
Page 62: ...RELIANCE Omni Light Maintenance 52 Copyright ADB SAFEGATE All Rights Reserved ...
Page 70: ...RELIANCE Omni Light POWER TABLE 60 Copyright ADB SAFEGATE All Rights Reserved ...
Page 72: ...RELIANCE Omni Light CABLE LOSS 62 Copyright ADB SAFEGATE All Rights Reserved ...
Page 76: ......