Appendix B: POWER TABLE
This load must be considered when calculating the total CCR load.
CAUTION
The RELIANCE fail-open is not to be connected to transformers larger than 100 W (-v2.3), 200 W (v3.0. A correct
calibration of the CCR is important to achieve an accurate fail open response.
Fixture type – 1 cordset
Fixture load
Isolation transformer
CCR load
Size
Load
Efficiency
Approach white
64 VA
65 W
11 VA
0.85
75 VA
Approach red
42 VA
46 W
8 VA
0.85
50 VA
Runway centerline, L-850A(L),white/white
23 VA
25 W
10 VA
0.7
33 VA
Runway centerline, L-850A(L), white/red
18 VA
25 W
8 VA
0.7
26 VA
Runway touchdown zone, L-850B(L)
15 VA
15 W
6 VA
0.7
21 VA
Runway RETIL
12 VA
15 W
5 VA
0.7
17 VA
Runway edge, L-850C(L)
53 VA
45 W
9 VA
0.85
62 VA
Displaced threshold, L-850C(L)
40 VA
45 W
7 VA
0.85
47 VA
Runway threshold/end, L-850D(L)
30 VA
45 W
5 VA
0.85
35 VA
Runway threshold/end, ICAO
60 VA
65 W
11 VA
0.85
71 VA
Runway threshold, L-850D(L)
21 VA
25 W
9 VA
0.7
30 VA
Runway threshold, ICAO
51 VA
45 W
9 VA
0.85
60 VA
Runway threshold wingbar, ICAO
52 VA
45 W
9 VA
0.85
61 VA
Runway end, L-850D(L), red
18 VA
25 W
8 VA
0.7
26 VA
Runway end, L-850D(L), red/red
27 VA
45 W
5 VA
0.85
32 VA
Runway status, takeoff, intersection L-850T(L) 15 VA
15 W
6 VA
0.7
21 VA
Stopway ICAO
22 VA
25 W
10 VA
0.7
32 VA
Taxiway centerline narrow, L-852C(L)
12 VA
15 W
5 VA
0.7
17 VA
Taxiway centerline curved, L-852K(L)
14 VA
15 W
6 VA
0.7
20 VA
Taxiway centerline wide
1
15 W
6 VA
0.7
20 VA
Taxiway centerline lead-in, L-852D(L)
15 VA
1
15 W
6 VA
0.7
21 VA
Runway guard light, L-852G(-L)
21 VA
25 W
9 VA
0.7
30 VA
Stopbar ICAO
14 VA
15 W
6 VA
0.7
20 VA
Stopbar L-852S(L)
16 VA
15 W
7 VA
0.7
23 VA
Notes
1
Depending on color and if it is a bi- or unidirectional fixture
Fixture type – 2 cordset
Fixture load
Isolation transformer
CCR load
Size
Load
Efficiency
Runway centerline, L-850A(L), white/white
12 + 12 VA
2 × 15 W
2 × 5 VA
0.7
2 × 17 VA
Runway centerline, L-850A(L), white/red
12 + 6 VA
2 × 15 W
5 × 3 VA
0.7
17 + 9 VA
Runway edge, L-850C(L), white/white
27 + 27 VA
2 × 45 W
2 × 5 VA
0.85
2 × 32 VA
UM-0210, Rev. 2.0, 2020/04/30
39
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......