Connect a PC to the SCM unit
Using the cable supplied (RS-232), connect the shorter cable end with LOAD/RESET (591836) to the PC and the longer cable
end to the LPC.
Figure 7: PC and SCM unit
Rs232 Cable
COM 1
COM 1
SCM
Note
For more information, see the marking on the LOAD/RESET box.
Connect the LPC to a RELIANCE IQ product
1. Using the cable supplied (594115), connect to Output 1 or Output 2 to a RELIANCE IQ product.
Note
The short circuit plug should be connected to the output NOT in use, either Output 1 or Output 2. The two
outputs are connected in series to give equal functionality.
2. Make sure the Remote button (2) on the LPC is NOT pressed in (off) before you start programming.
3. Turn on the Power button (3).
Figure 8: Back of the LPC and RELIANCE IQ product
2.
3.
UM-0210, Rev. 2.0, 2020/04/30