3. Remove the top cover from the bottom cover.
4. Remove the O-ring gasket from the bottom cover, see
Figure 9: Fixture upside down
Figure 10: Lift up housing
Figure 11: Remove gasket
Replace
1. Carefully clean all contact surfaces of the light fixture and of the housing.
2. Install a new O-ring gasket on the bottom cover.
Note
The O-ring gasket must be changed each time the light fixture is disassembled.
3. Connect the LED board cable connector(s) to the Supply Terminal(s) of the converter in the housing. Note the orientation
and alignment of the LED board cables, which are different between 1 connector and 2 connector versions.
Converters with 1 connector: the cables should have colored wires towards each other and crossed.
Converters with 2 connectors: the cables should have colored wires away from each other and crossed. Light fixtures
with only one LED-board need to have its LED-board connected to the LED B channel, see
. Place the top cover
over the bottom cover, align A and B sides on the top cover with the corresponding sides on the bottom cover.
Note
Before closing the light fixture, it is important to make sure the O-ring is placed correctly in the groove of the
bottom cover to prepare the light fixture for water tightness checks and use in the airfield. For more information,
see
Figure 12: Converter with 1 connector
Figure 13: Converter with 2 connectors
4. Put the light fixture on a surface with the top cover facing down, see
.
UM-0210, Rev. 2.0, 2020/04/30
27
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......