6. After installation, make sure that each light fixture functions properly.
7. In order to bond the light fixture to ground, use the supplied screw (Torx M4×6 mm, Torque 2.5Nm) to attach the braided
ground strap to the grounding point on the light fixture. The grounding point is indicated by a grounding symbol and
located on the bottom side.
Remove the fitting from the base
CAUTION
Fall- and trip hazard! When a light fixture has been removed, the base must be fitted with a cover designed for this
purpose or with a spare light fixture.
1. Remove the light fixture from the base using two large flat blade screwdrivers.
2. Disconnect the secondary supply connector.
3. Remove and check the O-ring gasket.
Note
It is recommended to change the gasket, lock nuts or bolts each time the light fixture is removed or dismounted from
the base. For more information, see
.
CAUTION
Use of incorrect combination of gaskets, bolts and nuts can create severe damages to the product installation and
create multiple safety risks.
Make sure to know what base the light fixture will be installed in, in order to chose the correct gasket, bolts and nuts.
Failure to follow these cautions can result in equipment damage or aircraft FOD. For more information, see
4.4 Toe-in
Toe-in of light fixtures can be achieved in two ways:
1. By installing the light fixture in runway/taxiway parallel bases and use light fixtures with built in toe-in.
2. By installing the light fixture in bases installed at an angle relative the runway/taxiway and use light fixtures with no built
in toe-in.
If bases which are installed at an angle are used, provided that they are installed correctly, straight light fixtures, i.e. with no
toe-in, should be used.
The following chapter only regards the case where light fixtures are installed in runway/taxiway parallel bases, i.e. where no
toe-in is achieved by angled bases.
UM-0210, Rev. 2.0, 2020/04/30
13
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......