Replace
1. Lubricate the new prism gasket with CC Patron grease.
2. Place the prism gasket in the prism opening in the top cover.
3. Put the new prism into the new prism gasket, then push it all the way into the opening and hold for about a minute. See
Figure 20: New prism into prism gasket
4. Check that the O-ring of the prism gasket is even in the chambered area.
5. Place the new Teflon protective plate and steel plate over the prism and prism gasket and tighten the two M5x12 screws
to a torque of 4.5 Nm.
6. Looking from above, make sure the prism edge is parallel with the prism holder, see
Figure 21: Prism holder edge
7. Use alcohol based cleaner to remove any grease or dust from the prism.
8. Attach the LED board holder, including screws, and gently tighten the screws on the LED holder in sequence following
number 1
‑
4, see
.
9. Tighten the same screws to a torque of 4.5 Nm following number 5
‑
8, and re-tighten the two screws on the steel plate to
4.5 Nm. See
.
Figure 22: Tighten screws in sequence
UM-0210, Rev. 2.0, 2020/04/30
31
Copyright
©
ADB Safegate, All Rights Reserved
Summary of Contents for RELIANCE AC
Page 2: ......
Page 8: ...RELIANCE Inset Lights List of Figures viii Copyright ADB Safegate All Rights Reserved ...
Page 10: ...RELIANCE Inset Lights List of Tables x Copyright ADB Safegate All Rights Reserved ...
Page 20: ...RELIANCE Inset Lights Introduction 10 Copyright ADB Safegate All Rights Reserved ...
Page 46: ...RELIANCE Inset Lights Spare Parts 36 Copyright ADB Safegate All Rights Reserved ...
Page 48: ...RELIANCE Inset Lights INTEROPERABILITY 38 Copyright ADB Safegate All Rights Reserved ...
Page 52: ...RELIANCE Inset Lights CABLE LOSS 42 Copyright ADB Safegate All Rights Reserved ...
Page 55: ...UM 0210 Rev 2 0 2020 04 30 45 Copyright ADB Safegate All Rights Reserved ...
Page 56: ......