![Adaptec DuraStor 6220SS Installation And User Manual Download Page 104](http://html.mh-extra.com/html/adaptec/durastor-6220ss/durastor-6220ss_installation-and-user-manual_2846908104.webp)
5-5
Maintaining the DuraStor Storage Subsystem
2
Grasp the screws and pull the cooling fan module from the
RAID appliance. See
Figure 5-7
.
Figure 5-3. Removing the Cooling Fan Module
3
Align the replacement cooling fan module with the open bay
and push the module into the RAID appliance until it seats
completely.
4
Tighten the screws on the cooling fan module.
Do not
overtighten.
The Fault LED on the front bezel goes out.
Replacing a Power Supply Unit
When a PSU fails
■
The alarm sounds.
■
The Fault LED on the front bezel lights up.
■
The system monitor displays an error event.
A failed PSU should be replaced as quickly as possible to maintain
power system redundancy.
Note:
PSUs are hot-swappable.
1
Remove the front bezel. See
Removing the Front Bezel
on page 3-3
.
2
Turn off the affected PSU.
3
Squeeze the PSU’s release latch.
Ext
Int
HOST OUT (CH 0)
HOST OUT (CH 3)
HOST IN (CH 0)
HOST IN (CH 3)
DISK CH 2
DISK CH 1
SERIAL B
SERIAL A
DuraStor IUG.book Page 5 Wednesday, January 30, 2002 10:49 AM