700002 Rev. F
© 2012 ADA EZ. ALL RIGHTS RESERVED.
43 of 56
NOTE
The LED bar will indicate minimum and maximum values as adjustments are made. Green indications are
within ANSI standards. Red indications are outside ANSI standards.
OP & CLS TIME range is 3.5 to 13 seconds (open and close times are calculated during the autotune
process).
HOLD OPEN time range is 1 to 30 seconds (default = 5 seconds).
8.3.1
TEST operator to confirm desired results. If necessary, REPEAT adjustment.
8.4
Setting
Optional Functions – Power Close, Push & Go, and Dynamic Braking
NOTE
The ADA EZ must be plugged in to the transformer if the POWER CLOSE or PUSH AND GO features
are enabled.
POWER CLOSE will apply a closing force on the door if the door did not fully close in the normal closing
time. Power close will activate and turn off when the door is fully closed or if the door does not move
after attempting to close for two seconds.
PUSH AND GO will cause the door operator to initiate an automatic open cycle when the door is pushed
in the open direction.
DYNAMIC BRAKING will apply braking to the door when the door speed exceeds four times the
programed automatic opening time under abusive opening conditions or wind.
8.4.1
ENABLE or DISABLE Power Close (factory default is OFF):
a.
PRESS and HOLD “SELECT” and “ENTER” for 3 seconds to enter programming
mode. LEDs DS8 through DS11 shall flash green briefly.
b.
WAIT for the “CLS” LED to illuminate.
c.
PRESS and RELEASE the “SELECT” pushbutton to advance until the “PC, PG,
DB, XY” LED
AND
DS8 LED illuminate to set the Power Close function.
d.
ROTATE the potentiometer to change the state of the LED. The green LED shall
illuminate to indicate that Power Close function is ON. The red LED shall illuminate
to indicate that the Power Close function is OFF.
e.
PRESS and RELEASE the “ENTER” pushbutton to store the setting.
f.
PRESS and HOLD the “ENTER” pushbutton for three seconds. The operator shall
exit programming mode.
8.4.2
ENABLE or DISABLE Push & Go (factory default is OFF):
a.
PRESS and HOLD “SELECT” and “ENTER” for 3 seconds to enter programming
mode. LEDs DS8 through DS11 shall flash green briefly.
b.
WAIT for the “CLS” LED to illuminate.
c.
PRESS and RELEASE the “SELECT” pushbutton to advance until the “PC, PG,
DB, XY” LED
AND
DS9 LED illuminate to set the Push & Go function.
d.
ROTATE the potentiometer to change the state of the LED. The green LED shall
illuminate to indicate that Push & Go function is ON. The red LED shall illuminate
to indicate that the Push & Go function is OFF.
e.
PRESS and RELEASE the “ENTER” pushbutton to store the setting.