51
Oil warning light (RED)
When the oil level falls below the
lower level, the oil warning light
comes on and the engine stops
automatically. Unless you refill with
oil, the engine will not start again.
Overload indicator light (RED)
The overload indicator light comes
on when an overload of a
connected electrical device is
detected, the inverter control unit
overheats, or the AC output voltage
rises. If this happens, the AC
protector will trip, stopping power
generation in order to protect the
generator and any connected
electric devices. The AC pilot light
(Green) will go off and the overload
indicator light (Red) will stay on, but
the engine will continue running.
TIP:
If the engine stalls or does not start, turn the engine switch to “ON” and then pull the
recoil starter.
If the oil warning light flickers for a few seconds, the engine oil is insufficient. Add oil and
restart.
When the overload indicator light comes on and power generation stops, proceed as
follows:
1. Turn off any connected electric devices and stop the engine.
2. Reduce the total wattage of connected electric devices to within the rated output.
3. Check for blockages in the cooling air inlet and around the control unit. If any blockages
are found, remove.
4. After checking, restart the engine.
TIP:
The overload indicator light may come on for a few seconds at first when using electric
devices that require a large starting current, such as a compressor or a submergible pump.
However, this is not a malfunction.
5. CONTROL FUNCTION:
5. CONTROL FUNCTION:
AC pilot light (GREEN)
The AC pilot light
①
comes on
when the engine starts and
produces power.
DC protector
The DC protector turns to “OFF”
②
automatically when an electric
device being run by the generator is
operating and excess current is
drawn. To use this equipment again,
turn on DC protector by pressing its
button to “ON”
①
①
“ON”
Direct current is output.
②
“OFF”
Direct current is not output.
Reduce the load of the connected electric device to below the specified rated output of
the generator if the DC protector turns off. If the DC protector turns off again, stop using
the device immediately and consult an authorized dealer.
WARNING:
Summary of Contents for AGi2100
Page 2: ...Italiano Fran ais English Deutsch Espa ol 3 39 75 111 147...
Page 39: ...39 12 SCHEMA ELETTRICO...
Page 78: ...78 12 ELECTRIC DIAGRAM...
Page 117: ...117 12 SCH MA LECTRIQUE...
Page 156: ...156 12 SCHALTPL NE...
Page 195: ...195 12 DIAGRAMAS DE CABLEADO...
Page 198: ...Notes...
Page 199: ...Notes...