2.2 Front Console LED
Display
Indicator Light.
Torque Display. (Always displays torque value)
Secondary Display.
Parameter Setting (PSet)/Job display and
Increment/Decrement buttons.
Toggle button
Indicator Lights:
Green LED:
Indicates fastening cycle meets specified
parameters.
Red LED:
Indicates fastening cycle rejected for
exceeding high torque.
Red Flashing LED:
Indicates low torque. Fastening cycle was
rejected for not achieving low torque.
Yellow LED:
Indicates
High Angle. Fastening cycle was
rejected for exceeding high angle.
Yellow Flashing LED:
Indicates Low Angle. Fastening cycle was
rejected for not achieving low angle.
Blue LED:
Tool is In-cycle, above threshold.
•
Increment and Decrement buttons change pset.
•
Toggle button switches
secondary display
between
o
Units of measure
o
Ethernet IP address
o
USB (System Port) IP address
o
COMP: Torque Compensation Tare Value (See details in AC_TCOMP Stage)
o
Angle report
NOTE:
If Jobs are enabled refer to
4.3 Job
section of the manual for Toggle Button