Page
115
of
125
Pulses High
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Pulses High” output assignment will go active at the completion of a fastening that has an pulse
count that exceeds the high limit. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.
Pulses Low
Supported Feature
Bus Element Bit
0-32
Polarity
N.O.,
N.C.
Mode
Normal,
Timed,
Flash
Time Width Offset Input
Bus
Input
Element
Input
Bit
√
√
√
√
√
The “Pulses Low” output assignment will go active at the completion of a fastening that has an pulse
count that falls below the low limit. It will go inactive when the next fastening is started (the torque
exceeds the threshold value) or a Job reset.
11.1 Controller supported MIDs
Supported MID
MID
Description
Revisions
Note
1 Communication start
1,2,3
2 Communication start acknowledge
1,2,3
3 Communication stop
4 Command error
5 Command accepted
10 Parameter set ID upload request
11 Parameter set ID upload reply
14 Parameter set selected subscribe
15 Parameter set selected
16 Parameter set selected acknowledge
17 Parameter set selected unsubscribe
18 Select Parameter set
19 Set Parameter set batch size
20 Reset Parameter set batch counter
30 Job ID upload request
31 Job ID upload reply
34 Job info subscribe
35 Job info
36 Job info acknowledge