IEC (AcraDyne DC Tool) Specific Fault Codes
CODE
Fault Type
Description
Possible Causes
FT01
Tool not connected Tool communication
timeout
•
Tool not connected
•
Faulty tool cable
•
Faulty tool electronics or
wiring
FT02
Invalid TID
parameters
Tool parameter file not
compatible with
Controller
•
Corrupt tool ID memory
location
•
TID file not loaded in tool
FT04
Torque signal out of
Range
Tool torque signal voltage
is beyond electrical limits
•
Tool not connected
•
Faulty tool cable
•
Faulty transducer
•
Transducer electronics not
calibrated
•
Faulty tool/controller
electronics or wiring
FT05
Torque tare value
out of range
Tool torque signal no load
voltage is out of range
•
Transducer electronics
significantly out of calibration
•
Faulty transducer
•
Faulty tool cable
•
Tool gear binding
•
Faulty controller electronics or
wiring
FT06
Motor hall states
invalid
Hall signals states are all
high or all low
•
Tool not connected
•
Faulty tool cable
•
Faulty tool electronics or
wiring
•
Faulty motor halls or wiring
FT07
Motor halls skipping
states
Hall signal sequence
incorrect
•
Faulty tool cable
•
Faulty tool electronics or
wiring
•
Faulty motor hall or wiring
•
Hall signal leads are
connected incorrectly
•
Too many tool extension
cables
FT08
Tool ground not
connected
Tool ground conductors
not connected
•
Tool not connected
•
Faulty tool cable
•
Faulty tool ground wires
•
Faulty tool electronics or
wiring
FD12
Drive not
connected
Drive CAN
communication time out
•
Faulty Controller main board
electronics
•
Faulty drive electronics or
connection
FD13
Drive Fault SW
Drive reporting fault via
CAN communication
•
Tool not connected
•
Faulty tool cable
•
Faulty tool motor
•
Application exceeds
capability of drive