4.6.5 Torque Calibration Routine
Used to calibrate tool using a Master Transducer. The
following are steps to calibrate tool.
1. Press the “Start Calibration” button.
2. Run Tool to Final Torque.
3. Enter external transducer (Master) value in Measured
Torque
box.
4. Press “Send New Cal Values to Tool” button.
5. ‘New Ca’l value is calculated automatically and assigned
to tool ID Board.
4.6.6 Indicators
Allows user to test tool LEDs, headlight and buzzer.