4.5.3.3 Serial
•
Port Mode:
The following modes are available:
Serial Output
:
A serial data string will be Output in
the following format after each rundown:
•
# P 1 BB TTT.T AAAA 0000 0000 J
(Notice the decimal point next to the least
significant T)
•
P:
Parameter set (“1” – “9”) for PSets 1-9,
(“A” – “W”) for PSets 10-32.
•
B:
Job count
•
T:
Torque result
•
A:
Angle result
•
J:
Judgment (@=overall pass, H=low torque,
I (eye)=hi torque, J=low angle, K=hi angle)
Barcode Reader:
(See Section 5.0 for Barcode
setup)
Serial Output and Barcode Reader.
Open Protocol:
(See 4.5.4.1 for details on Open
Protocol)
•
Baud
: Serial ports can be configured for different
baud rates available.
•
Output Followed By Null Control Character
Adds a one-byte NULL character to the end of the serial string. Needed by
systems that use the NULL character to signify the end of the string.
•
Send PSet Change
Sends a serial string any time the PSet is changed. String is in the form
‘%%CAN8X%%%%CAN4YNAC%%’ where X is the previous pset and Y is the new
pset.