174 AO1 Over-Ranging
0 = Over Ranging Disabled
1 = Over Ranging Enabled
2 = Over Ranging enabled and currently active
175 AO2 Over-Ranging
176 AO3 Over-Ranging
177 Heater Set Point
Cell Heater Set Point units in °C
178 PMT High Volt. Pot
High voltage pot setting
179 PMT Test LED Pot
PMT Test LED intensity controller POT
180 Last Power Failure
Time Stamp of the Last power fail (4 byte time
stamp)
Bit 31:26 ---- Year (0 – 99)
Bit 25:22 ---- Month ( 1 – 12)
Bit 21:17 ---- Date (1 – 31)
Bit 16:12 ---- Hour (00 – 23)
Bit 11:06 ---- Min (00 – 59)
Bit 05:00 ---- Sec (00 – 59)
181 Inst Manifld Pres.
Manifold Pressure in S40 instruments
(instantaneous)
182 Cell Press. (gas5)
Cell Pressure for Gas 5 (Nx)
183 Gas 4 Inst.
Calculated gas concentration currently displayed
on front screen E.g. NH3
184 Gas 4 Avg.
Average of the readings (for Gas 4) of the last n
minutes where n is the averaging period E.g. NH3
185 Gas 5 Inst.
Calculated gas concentration currently displayed
on front screen E.g. Nx
186 NH3 Conv. Efficiency
187 Cell/Lamp Duty Cycle
188 Mirror T. Duty Cycle
189 Flow Temp Duty Cycle
190 Cooler T. Duty Cycle
191 Conv Temp Duty Cycle
192 CO Conv T Duty Cycle
193 F/Scale Curr AO 1
20 mA Calibration value
194 F/Scale Curr AO 2
195 F/Scale Curr AO 3
196 Z Adj Curr AO 1
4 mA Calibration value
197 Z Adj Curr AO 2
198 Z Adj Curr AO 3
199 Ext Analog Input 1
The value of the external analog input after the
multiplier and offset have been applied
200 Ext Analog Input 2
Summary of Contents for Met One Instruments GAS-1060
Page 10: ...Serinus 60 User Manual 3 0 Page 10 This page is intentionally blank...
Page 18: ...Serinus 60 User Manual 3 0 Page 18 This page is intentionally blank...
Page 35: ...Installation Page 35 Figure 7 Switching the Battery On Off...
Page 36: ...Serinus 60 User Manual 3 0 Page 36 This page is intentionally blank...
Page 102: ...Serinus 60 User Manual 3 0 Page 102 This page is intentionally blank...
Page 134: ...Serinus 60 User Manual 3 0 Page 134 9 5 Plumbing Schematic PN D020060...
Page 135: ...Parts List Page 135 9 6 Block Wiring Schematic PN D020111...
Page 136: ...Serinus 60 User Manual 3 0 Page 136 9 7 Measurement Cell Side Section PN H015000...
Page 137: ...Parts List Page 137...
Page 139: ...Parts List Page 139 9 9 Valve Assembly Exploded View PN H010042...
Page 140: ...Serinus 60 User Manual 3 0 Page 140 9 10 High Pressure Valve Exploded View PN H050043...