Gen II
User Manual
11-3 – Fan Blade Mapper
Chapter 11
Revision 3.00, Apr 2020
11.1.2.3.
In the
Name:
field, use the analyzer keypad to enter a name for this setup. The
engine model is usually a good choice for this name.
11.1.2.4.
In the
Number of Blades:
field, use the analyzer keypad to enter the total number
of blades on the disk. The field will accept values from 5 to 99. If an even number
of blades are entered, the
Define Max Weight Difference:
field will become
visible.
11.1.2.5.
In the
Blade Num Style:
field, use the [
] key to select the numbering style you
would prefer to use for this setup. The choices are <A – Z>, which will allow up
to 26 blades, or <B1 – B99> which will allow up to 99 blades in a set. This
numbering style is how you will identify each blade in the set for weight and later
for location placement.
11.1.2.6.
In the
Units of Measure:
field, use the keypad to enter the units of measure you
wish to use for the blades, such as Inch Grams.
11.1.2.7.
In the
Max Total Error:
field, use the analyzer keypad to enter the maximum
total error for the distribution AFTER the blades have been reshuffled. If you do
not know the maximum allowable error, the default 0.7 is generally acceptable for
all distributions. This error is used as the target for the reshuffle and keys the
analyzer to continue calculations until this limit is either met, or cannot be
achieved.
11.1.2.8.
In the
Include S/N Field:
, use the [
] key to select either “Yes” or “No”.
Selecting “Yes” will allow the user to enter in Blade Serial numbers as shown in