Gen II
User Manual
10-17 – Fan/Turbine Balance
Chapter 10
Revision 2.10, Apr 2020
10.1.6.10.
Use the [
] key to select the “
Ch
” (Channel A, B, C, or D) where you will
connect the sensor input from the vibration sensor in this same row. Use the [
]
key to move to the next field.
10.1.6.11.
Use the keypad to enter a name in the “
Desc
” (Description) field. The name
should reflect the source, location, or other common attribute of this sensor input.
Some suggestions are FRONT, REAR, VERT, HORIZ, or FFV, FFH. Use the [
]
key to move to the next field.
10.1.6.12.
In the “
Pos
” field, use the [
] key to select the clock position of the sensor on the
engine as viewed from forward of the engine looking into the intake. Use the [
]
key to move to the next field.
10.1.6.13.
Use the keypad to enter a value in the “
Targ
” field. The value will define the
point where the analyzer provides a suggestion to terminate the balance job.
When all fields are complete, press [OK] to continue.
10.1.7.
– Define Fan/Turbine Balance ICFs Screen
NOTE
If an Influence Coefficient has not been defined or if “Select in Job” was selected in 10.1.1.11
above, the fields will be available for edit. If an Influence Coefficient has not been defined or if
balance speeds were selected in 10.1.1.11 above, you will have to press [F3] “Edit” to edit the
fields.
10.1.7.1.
The “
Plane ID
:” field displays the identifying number for the balance plane being
configured.