Gen II
User Manual
10-26 – Fan/Turbine Balance
Chapter 10
Revision 2.10, Apr 2020
10.1.14.2.
The function keys operate as described below:
[F1] “Inst=None” key – This will return all “Installed” values to the null or “0” weight.
Once pressed, the [F1] menu will change to “Inst=Sugg”. This will return all “Installed”
values to the values listed under the center “Suggest” column.
[F3] “Edit Weight” key – Allows you to identify missing weights from the class weight
set currently being used. Use the [
] or [
] keys to move from weight to weight. When
you reach a weight that is not available, use the [
] and [
] keys to place an -X- in the
field replacing the class weight number. Class weights marked with an X will be
excluded from the calculated solution. Using the solution example shown above, the
“416” weight has been identified as unavailable in the screenshot below on the left. After
pressing [OK], the analyzer calculates a new solution using the available weights as
shown in the screenshot below on the right.