Gen II
User Manual
7-28 – Main Rotor Track & Balance
Chapter 7
Revision 3.00, Apr 2020
performed, or skipped. If the analyzer presents a solution and you choose not to apply it on the
current run, you are required to zero out the adjustment entries in the recording screen for that
particular adjustment. If you believe that the current ICFs are correct and the impact of one
adjustment on another will be minimal, it is possible to make multiple adjustments during a
single run by pressing the [F1] “All Adj” key.
7.2.7.1.
– Example Solution Screen #1
For our sample job, the first adjustment given is for a Lateral measurement at Idle – 103%N2.
The adjustment type to be applied is “LFL” or Lateral Flats of a damper sweep. The line at the
bottom of the screen serves as a reminder that a positive suggested solution equals adding
weight, Sweep Aft, Blade (pitch link) up, and Tab up.
For this measurement, the analyzer’s recommended adjustment is to adjust the Yellow blade by
0.06 flats and the Green blade 4.88 flats .
- If you are able to make this adjustment
exactly
as entered, press [F1] to install the suggested
solution.
- If an adjustment is made
other
than the suggested solution, you must enter the actual
adjustment in the appropriate “Installed” field using the keypad.
When finished Press Ok to continue.
[F1] “Inst=Sugg” key will populate the Installed field with the suggested solution
presented by the analyzer. It can also be used return any “Installed” field that has been
edited to the original values presented by the analyzer.