51
7.
Table of technical problems
STATUS OF THE BOILER INCONVENIENCE
E 02
The water pressure in the heating system is too low
E 03
System pressure too close to the maximum limit.
E 04
DHW probe fault
E 05
Delivery probe failure
E 14
Smoke probe failure
E 13
Smoke probe intervention
E 15
Fan failure (feedback / power)
E 06 +
No ignition
E 07 +
The safety thermostat has tripped
E 08 +
Flame error
E 09
No water circulation in the system
E 16
Return probe failure
E 20
System overtemperature
E 21
Delta T CH/Ret > TSP82 (1)
E 11
Gas valve modulator is disconnected
E 12
Storage tank probe fault
E 19
DHW flowmeter error
E 28 +
Exhausted attempts to unlock from the boiler interface
E 37
Supply voltage too low
E 40
Incorrect network frequency
E 41 +
Flame loss for more than 6 consecutive times
E 42
Keys fault
E 43
OT communication error
E 44 +
SGV opening time without flame error
E 62
Combustion calibration request
E 96
Smoke outlet obstruction
E 72 +
The ΔT between delivery and return does not fall within the limit conditions
E 88 +
SGV management circuit failure
E 80 +
SGV opening problem
E 81 +
Shutdown due to combustion problems on ignition (2)
E 87 +
SGV circuit problem
E 91 +
Flame loss for more than 6 consecutive times (with max ignition correction ON)
E 98 +
SW error / board error
E 99 +
Generic fault
Table 28 - Table of technical problems
(1) This control is activated 120 seconds after the activation of the pump and only during the request for CH (without domestic hot water).
(2) Fault 81 can be caused by an obstruction in the flue gas outlet. In this case it is advisable to contact the assistance center before
unlocking the boiler.
ATTENTION
Gas boilers are electrical and electronic devices (EEE) and when they are decommissioned they become electrical and electronic waste
(WEEE): as such they must be disposed of in compliance with current legislation.
Gas boilers are classified as domestic appliances and must be disposed of together with washing machines, dishwashers and dryers
(WEEE R2 waste).
The dismantling of gas boilers and their disposal through channels not specifically provided for by law is prohibited by law.
The user has the right to be able to confer the decommissioned gas boiler, intact in its construction, in the ecological island of the
municipality in which he is a resident.
The installer and the user have the right to be able to deliver the decommissioned gas boiler, intact in its construction, on a one-to-one
basis, to the point of sale where they purchase the new gas boiler.