93
PROGRAMMING
AUTO MODE (LOW TEMPERATURE TRIGGER)
Pressing the up or down button sets the low
temperature trigger. The devices will activate if the
probe’s reading meets or falls below this threshold.
Once triggered, the devices will gradually ramp up
to the level set in ON mode. If the probe’s reading
rises above this trigger point, the devices will
gradually slow down to a stop or at the level set in
OFF mode.
You may set this trigger above the high
temperature trigger to create a specific range in
which the devices are active.
This is typically used with devices like heaters
and seedling mats to help raise the temperature
when it gets too cold. For example, if you set a
low temperature trigger of 78°F, then your device
will activate when the temperature falls to 78°F
or lower, and turn off when it rises above 78°F.
Products shown here may still be in development.
Any of the four trigger points can
activate while you are in AUTO
Mode, even if you are viewing
another trigger point. Please set
a trigger point to OFF if not in
use, by holding down the up and
down button. If there is a level
set in OFF Mode other than zero,
the devices will run at that level
when triggered to turn off.
LOW TEMPERATURE
TRIGGER POINT
32
194
COLDER
HOTTER
ON
OFF
78
CONTROLLER 69 PRO
Summary of Contents for Advance Grow Tent Kit
Page 1: ...USER MANUAL ADVANCE GROW SYSTEM COMPLETE INDOOR PLANT KIT...
Page 2: ......
Page 12: ...12 CLOUDLAB SERIES ADVANCE GROW TENT...
Page 25: ...25...
Page 26: ...26 CLOUDLINE MIXED FLOW INLINE FAN SYSTEMS CLOUDLINE A4 shown...
Page 40: ...40 DUCT CARBON FILTER PREMIUM AUSTRALIAN CHARCOAL...
Page 51: ...51...
Page 52: ...52 IONBOARD IONFRAME EVO GROW LIGHT SYSTEM IONBOARD S22 shown...
Page 67: ...67...
Page 68: ...68 CLOUDRAY OSCILLATING FAN SYSTEM...
Page 78: ...78 CONTROLLER 69 PRO UISTM MULTI DEVICE CONTROLLER...
Page 126: ......
Page 127: ......
Page 128: ...www acinfinity com...