Please read the operating instructions of the SE1000.
Please take care that you use the pulse setting for the
keyswitch.The circuit shown above enables you to
activate/deactivate the alarm system by turning the key in
either direction. Here too, the tamper line is not yet
connected to the system. The setting of the relais outputs
and additional switch outputs is shown later.
In the following, we show you the wiring of the tamper line.
Make sure that you connect all tamper contacts of the
individual components in series. The siren and flashlight
are an exception here since a special tamper connection
is provided on the equipment. The following diagram of
the motion sensor and key switch shows the connection of
the tamper contacts. The door contact sensor has no
tamper connections!
If you just want to use sensors without a tamper contact,
insert a jumper between COM and A/T on the alarm
system.
Before programming the equipment, read the following
description of how to connect the siren and flashlight to
the Terxon MX. For this purpose, we use the SG1650.
The tamper line of flashlight and siren is connected via a
separate tamper contact to the equipment. If you do not
want to use an external signalling device, place a jumper
between TR and GND (0V) of the alarm centre. The
following diagram shows the connection of the SG1650 to
the Terxon MX:
This completes the connection of the equipment.
We now come to the programming of the alarm
equipment. Make sure than the tamper contacts of all
components are closed before you connect the equipment
to the power supply. Proceed as follows:
1. Connect the 12V battery (7.0 Ah) to the contacts of
the alarm centre (note the colour code:
red = +12V, black = 0V).
2. Using a screwdriver, short-circuit the two pins of the
kick-start jumper (see p. 14).
3. The green LED for the power supply (
) begins to
flash and the buzzers of the control units can be
activated. You can ignore the display messages.
4. Enter the factory-set user code.
This is:
1234
. You can ignore the display messages.
5. First close the housing of the burglar alarm panel
securely before switching on the 230V voltage.
6. Switch on the 230V mains voltage to the burglar alarm
panel.
7. The green LED for the voltage (
) now lights
constantly.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...