33
UK
16.2 Overview of program menu
Country setting (000
n
)
Important: If you change the country setting, all system
settings are reset to the country settings of the new
country.
Menu item
Setting (n)
Meaning
000
0
UK – Great Britain
1
I – Italy
2
EE – Spain
3
P – Portugal
4
NL – Netherlands
5
FR – France
6
B – Belgium
7
D – Germany
8
CH – Switzerland
9
A – Austria
X1
IRL – Ireland
X2
OEM1
X3
OEM2
X4
FI – Finland
X5
N – Norway
X6
DK – Denmark
X7
S – Sweden
Zone setting (001 – 016, X17 - X32
nn
)
In zone programming, you first program the zone name
and then the zone property.
Menu item
Setting (nn)
Meaning
001 - 008
00
NU – Not Used
01
PA – Panic
02
Fr – Fire
03
NA – Immediate
04
24 – 24 hour
05
FE – Entry/exit
06
Er – Entry to follow
07
SA – Shock Analyser
08
Tc – Technical
09
KB – Keybox
10
SD – Fire alarm
Menu item
Setting (nn)
Meaning
11
KM – Key switch
12
KF – Block lock
13
AM – Anti Mask
14
FB – Forbikobler Zone
In addition to the zone properties, you program the zone
attributes.
Menu item
Setting (nn)
Meaning
X1
C – Chime
X2
S – Sensor test
X3
D – Double trigger
X4
O – Zone locks possible
X7
1…6 Sensitivity
B
Monitored in area B
C
Monitored in area C
D
Monitored in area D
Program code (020
nnnn
)
Menu item
Setting
Meaning
020
nnnn
Program code
Zone termination (021
n
)
Menu item
Setting
Meaning
021
0 No
resistor
NC
1
Two resistors FSL
Internal volume (022
n
)
Menu item
Setting
Meaning
022
0 Off
1…9
Quiet...Loud
Remote Reset (023
n
)
Menu item
Setting
Meaning
023
0 OFF
1
ON
Account Name (024
n
)
Menu item
Setting
Meaning
024
Account
name
x
return to progr. mode
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...