15
UK
Connection
Meaning
AC mains supply unit
(AC IN)
Contact for 230V main supply unit
Kick Start jumper
(KS)
Connect the two contacts of this jumper to start the alarm centre without a 230V mains power
supply.
Battery contact
(+ -)
Connecting plug from standby power supply
COMMS
interface
Contact for additional transistor outputs
Reset jumper
(NVM RST)
Connect the two contacts of this jumper to reset the alarm centre.
Fuses
(BAT F-2A / 12VAUX
F-1A)
Always use fuses of the same type. To avoid problems, make sure there is always a good
contact between the fuse holder and the fuse.
Siren sabotage input
(TR)
For sirens with their own power supply, connect this input direct to the tamper output of the
siren. Otherwise, connect the tamper contact of the siren to the loop between the TR input
and 0V. If no siren is used, connect the TR input direct to the 0V output.
Optional loudspeaker
(LS)
Connect a 16 Ohm loudspeaker for internal alerts.
Local download connection
(SK1)
You can connect a local PC here. The alarm centre can be configured using the downloader
program.
Connection for the telephone
connection
(RJ11 + A/B /
A1/B1)
RJ11 connection/screw connections for the telephone line
Programmable transistor output (OP).
Max. power consumption of all
transistor outputs 0.5A.
12V power supply for
components (e.g.
Tamper input for
ext. components
Alarm zones 1 – 8 for NC aöarm contact
(e.g. IR detector). No NO contacts can be
connected. Make sure alarm zones are
terminated with correct resistors. Two
different resistors, or no resistor, must be
used depending on the programming. If the
zone is used then the wire bridge should be
removed.
Sir.
ta
mper input
Opt
ional speaker
control unit
1A AUX fuse for
the power supply
2A BAT fuse for the
battery charging
AC
connectio
Kick
Star
Battery
connectio
COM
interface
NVM
EEPROM
tamper cover
contact
Local
Download
-
connectio
Connection for
telephone
connection
Programmable
floating relay
output (NC/NO) /
24VDC@1A
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...