57
UK
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
050 CSID code
To be able to use the remote reset function, you must set
the alarm centres to installer reset (function 33 to 1) and
assign the CSID code. To change the CSID code for a
deactivated alarm centre:
1. On the control unit, enter:
050
2. The LCD display shows: 050: CSID _
3. Via the keypad, enter the code. Enter 0 0 0 0 to
delete the code.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
051 Date and time
Proceed as follows to change the date and time:
1. On the control unit, enter:
051
2. The LCD display can show: 051: D03 M02 Y05
3. Via the keypad, select from the following items
and enter the date:
4. Confirm your input with
.
5. Enter the month via the keypad. (January to
September = 01 to 09)
6. Confirm your input with
.
7. Enter the year via the keypad.
8. Confirm your input with
.
9. The display changes; now enter the hour via the
keypad.
10. Confirm your input with
.
11. Enter the minute via the keypad.
12. Confirm your input with
.
13.
The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
052 Block tamper
Proceed as follows to change the property of the tamper
alarm:
1. On the control unit, enter:
052
2. The LCD display shows: 052:Omit Alarm
3. Via the keypad, select from the following items
and press:
0
Omit Alarm
You can only block some zones; a
tamper zone or a tamper alarm cannot
be blocked.
1
Omit Al+Tamp
You can block some zones and tamper
zones or a tamper alarm from
monitoring.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
053 Cancel - Reset
To change the property of the alarm reset:
1. On the control unit, enter:
053
2. The LCD display shows: 053:Abort=System
3. Via the keypad, select from the following items
and press:
0
Abort=System
Resetting after a cancelled alarm is as
set in function 33.
1
Abort=User
The user may make a reset after a
cancelled alarm.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...