75
UK
118 RemoteTel No 1
To change the settings:
1. On the control unit, enter:
118
2. The LCD display shows: 118:DL Tel No 1
3. Via the keypad, enter the telephone number.
Use key
A
to enter a 4-second pause (shown by
a comma).
u
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
119 RemoteTel No 2
See command 118.
120 RemoteTel No 3
To change the settings:
1. On the control unit, enter:
120
2. The LCD display shows: 120:DL No 3=OFF
3. Via the keypad, select from the following items
and press:
0
DL No 3=OFF
The alarm centre does not just accept
any remote telephone number.
1
DL No 3=ON
The alarm centre accepts any numbers
from remote PCs. The remote PC
transmits its number to the alarm centre
and the alarm centre uses this number
for the call back.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer mode.
123 Reset report
To change the settings:
1. On the control unit, enter:
123
2. The LCD display shows: 123:Restore OFF
3. Via the keypad, select from the following items
and press:
0
Restore OFF
The alarm centre does not
communicate any resets.
1
Restore ON
The alarm centre communicates resets.
(Function only with Scancom Fast
Format)
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
124 Switch open/close
To change the settings:
1. On the control unit, enter:
124
2. The LCD display shows: 124:Rev O/C OFF
3. Via the keypad, select from the following items
and press:
0
Rev O/C OFF
Open/Close not switched
1
Rev O/C ON
The function switches the commands
Open/Close for Scancom Fast Format.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...