8. Now enter via the control unit:
0
and then the factory-
set programming code
7890
The following shows on the display: Mult Syst?
9. Press Key 1 to create a partitioned system.
Press Key 0 to create a single system like we do.
10. The display shows: PROGR. MODE
11. You are now in the program menu of the burglar
alarm panel and can start programming
.
First we program the two zones.
On the keypad, enter 001 followed by
to make
settings to Zone 1 (motion sensor). You see the following
display:
You can now change the zone name “Zone01” using the
keypad of the control unit. The keys are similar in
operation to those of a mobile phone. Press C to move
one place forwards, and D one place back (see page 45).
Now press the Enter key
; the following appears:
Define Zone 001 as “immediate” by entering 03. You see
the following display:
By pressing keys A, B, C, D, you can change the
assignment of the sensor to the individual areas. . In this
programming example the detector works only when the
hole system is activated.. Now confirm your input by
pressing
. You are returned to the start screen of the
programming menu.
Now enter 002 for programming Zone 2, followed by
.
You see the following:
Change the name of the zone according to your wishes
and then press the Enter key
.
You see the following:
We will now change this to entry/exit. Enter 05. You see
the following in the display:
Now press B to add area B to the sensor. Confirm your
setting by pressing the Enter key
.
The “1” following the sub-areas stands for the time delay
group (1 to 4). You can change this at any time in the
programming menu (menu items 201 to 204, see page
82). You now have to program the key switch to Zone 3.
Enter 003, change the zone name if required, and press
the Enter key
. The display shows the following:
Change the zone by entering 11 in the key switch, and the
following appears:
Confirm your input with
. Note that non-connected
zones (004 to 008) are marked as “Not Used” (NU). You
can set a zone by entering 00.
In the next step, we set the exit delay time. This is the
time available for leaving the secure area before the alarm
system is activated.
In programming mode, enter 044 on the keypad, followed
by
. The display shows:
Enter an exit delay time (1 for 10 sec. to 6 for 120 sec.)
and confirm with
.
Set entry delay time under menu item 201.
In this example, you have 45 seconds to deactivate the
armed alarm system.
You can choose values from 10 to 120 sec. 1 stands for
10 and 6 for 120 seconds. After your selection, press
.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...