29
UK
If you use a loudspeaker with the system, you can test it in
the programming menu under item 094.
You have now made all settings in the programming
menu. Exit the programming menu by entering 099 and
confirming with
. You are now in the user menu.
We now add two users to the system. The first user
(BERND) is to activate and deactivate the system by
entering a code, the second (ANNA) using a chip key.
In the user menu, enter the administrator code 1234.
Now enter 4 on the keypad. The control unit shows:
Enter the user number of User 2. This is: X002. Press
. The display shows:
Now change the name on the keypad – in this case,
BERND.
Press the Enter key
.
You are now asked to enter a new code in the system.
Enter 1111 (for example) and confirm with
. This code
is for activating and deactivating the alarm system.
In the next step, we add User Anna, who is to activate and
deactivate the alarm system using a chip key. In the user
menu, enter the administrator code (1234) followed by 4.
You see the following:
Enter the user number of User 3. This is: X003. Press
. The display shows:
Now change the name to ANNA and press the Enter key
. The display shows:
After you press the Enter key, the display shows:
Hold the chip key in front of the control unit. You hear a
double tone. The chip key has been successfully
programmed. If required, you can also define a PIN for the
user. In this case, the user can choose between code and
chip key to activate/deactivate the alarm system.
To activate the Terxon MX, enter the code or hold the chip
key in front of the system. You see the following display:
By pressing “A” or
, you can now activate the
complete system. By pressing B, C or D, you can select
individual sub-areas. In this specimen installation, you
could for example activate sub-area B to arm the door
contact and thus monitor the exit doors.
The system is now fully installed and configured.
If you use SG1710 or SG1900 instead of SG1650, see the
following connection diagrams.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...