61
UK
alarm and the external siren are
activated.
2
B=Full
On alarm, the control units, the internal
signalling, the external sirens and the
telephone dialler are activated.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
065 Exit delay time internal B
To change the property of the exit delay time for internal
active B:
1. On the control unit, enter:
065
2. The LCD display shows: 065: Exit B=20
3. Via the keypad, select from the following items
and press:
1
Exit B=10
Exit delay time for internal active B is 10
seconds.
2
Exit B=20
Exit delay time for internal active B is 20
seconds.
3
Exit B=30
Exit delay time for internal active B is 30
seconds.
4
Exit B=45
Exit delay time for internal active B is 45
seconds.
5
Exit B=60
Exit delay time for internal active B is 60
seconds.
6
Exit B=120
Exit delay time for internal active B is
120 seconds.
4. Confirm your input. On the control unit, enter:
.
5. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
066 Forbikobler partitions
To change this property (only possible in partitioned
systems):
1. On the control unit, enter:
066
2. The LCD display shows: 066:Forbi 1 abcd
3. Via the keypad, select from the following items
and press:
A
Assign control unit of partition A.
B
Assign control unit of partition B.
C
Assign control unit of partition C.
D
Assign control unit of partition D.
4. Confirm your input. On the control unit, enter:
.
5. Repeat these steps for the remaining Forbikobler
control units.
6. The control unit acknowledges your input with a
double “beep” tone and shows Installer Mode.
067 Forbikobler correct
Proceed as follows to change the property of the
Forbikobler correct:
1. On the control unit, enter:
067
2. The LCD display shows: 067:Frb=Non-Appr
3. Via the keypad, select from the following items
and press:
0
Frb=Non-Appr
Proximity code key and user codes are
allowed for the access.
1
Frb=Approved
Only user codes are allowed for the
access (correct).
4. Confirm your input. On the control unit, enter:
.
Summary of Contents for Terxon MX
Page 10: ...10 D 8 bersicht der Geh usekomponenten 2 4 6 5 3 7 1 8 9...
Page 104: ...104 D...
Page 114: ...10 UK 8 Overview of housing components 2 4 6 5 3 7 1 8 9...
Page 210: ...10 FR 8 Vue d ensemble des composants du bo tier 2 6 3 7 1 8 9 4 5 FR...
Page 314: ...10 NL 8 Overzicht van de componenten van het huis 2 6 3 7 1 8 9 NL...
Page 381: ...77 NL Wijzigen van het volume bij een intern alarm 46 Zone instelling 44 Zonesabotage 49...
Page 392: ...10 DK 8 Oversigt over kabinetkomponenterne 2 4 6 5 3 7 1 8 9...
Page 484: ...102 DK...