Alliance Intelligent Battery Series
TM
User’s Guide
© 2020 American Battery Solutions Inc. All rights reserved. The data herein is intended as a guide and does not reflect the specification range for any particular property of this
product. Such data is based upon analysis of representative samples and not the actual product shipped. We based the information on data believed to be reliable on the date
compiled, but we do not represent, warrant, or otherwise guarantee, expressly or impliedly, the merchantability, fitness for a particular purpose, freedom from patent
infringement, suitability, accuracy, reliability, or completeness of this information or the products, materials or processes described.
Page 49
Table 15: Alliance Intelligent Battery Series™
Event Matrix cont.
Module
Event ID
(Hex)
Event Name
Charge
Charge
Entry
Drive
Drive
Entry
Regen
Full
Power
Platform
0x50C5
Abnormal Reset Reason
1
1
1
1
1
1
Platform
0x5015
Flash App CRC Error
0
0
0
0
0
0
Platform
0x5025
Flash Bootloader CRC Error
1
1
1
1
1
1
Platform
0x5035
Task Lockup
0
0
0
0
0
0
Platform
0x5045
RAM Over Utilization
1
1
1
1
1
1
Platform
0x5075
BMS Memory Error
0
0
0
0
0
0
Platform
0x5085
BMS Processor Failure
0
0
0
0
0
0
Battery
0x50A5
Event Logger Full
1
1
1
1
1
1
Battery
0x5095
Event Logger Almost Full
1
1
1
1
1
1
Battery
0x1125
Battery Brick Overcharged
0
0
0
0
0
0
Battery
0x1135
Battery Brick Over discharged
0
0
0
0
0
0
Battery
0x1145
Battery Brick Voltage Imbalance
1
1
1
1
1
1
Battery
0x1555
Battery Temperature Imbalance
1
1
1
1
1
0
Battery
0x1905
Battery Capacity Low (SOH-C)
1
1
1
1
1
1
Battery
0x1805
Battery Resistance High (SOH-R)
1
1
1
1
1
1
Battery
0x1705
Battery Pack Power Insufficient
1
1
0
0
0
0
Battery
0x181F
Battery Cell Soft Short
0
0
0
0
0
0
Charge
0x6305
Charge Undercurrent
0
0
1
1
1
1
Charge
0x6315
Charger Error
0
0
1
1
1
1
Charge
0x6335
Charger Comm Error
0
0
1
1
1
1
Allowed State for condition