Figure 12: Connecting multiple modules in parallel to a charger
When charging multiple batteries, maximum charge current should not exceed the
number of modules multiplied by the single module current limit for the number of
Alliance Intelligent Battery Series™ battery modules connected in any parallel
configuration. Alliance Intelligent Battery Series™ battery modules are only allowed
to connect in parallel and are not designed to connect in series.
Table 12: Max charge continuous current limits for multiple modules in parallel
Temperature (°C)
E48-2.0 model (Amps)
< 0
0
0
5.6 * # of modules
10
8.0 * # of modules
25
12.0 * # of modules
33
12.0* # of modules
40
20.0 * # of modules
45
20.0 * # of modules
50
12.0 * # of modules
> 50
0