![background image](http://html1.mh-extra.com/html/abs/alliance-e-series/alliance-e-series_user-manual_3491117040.webp)
Alliance Intelligent Battery Series
TM
User’s Guide
© 2020 American Battery Solutions Inc. All rights reserved. The data herein is intended as a guide and does not reflect the specification range for any particular property of this
product. Such data is based upon analysis of representative samples and not the actual product shipped. We based the information on data believed to be reliable on the date
compiled, but we do not represent, warrant, or otherwise guarantee, expressly or impliedly, the merchantability, fitness for a particular purpose, freedom from patent
infringement, suitability, accuracy, reliability, or completeness of this information or the products, materials or processes described.
Page 40
Charger Recommendation
Delta-Q IC-series CANOpen chargers are recommended for
Alliance Intelligent Battery
Series™
modules.
Charge Limits and Temperatures
At room temperature and above, the Alliance Intelligent Battery Series™ battery can
accept full rated charge. As with all battery technologies, charge acceptance is limited at
low and high temperatures. A permanent loss of capacity may be observed if charge
rates are not reduced at limited range of cell temperatures. As the cells’ temperature
falls into optimal temperature range during the charging process, they can gradually
accept higher currents. The Alliance Intelligent Battery Series™ batteries can be
charged with current limits shown in Table 11.
Table 11: Max charge continuous current limits for single module
Temperature (°C)
E48-2.0 model (Amps)
< 0
0
0
5.6
10
8.0
25
12.0
33
12.0
40
20.0
45
20.0
50
12.0
> 50
0
Charging Multiple Battery Modules in Parallel
Alliance Intelligent Battery Series
TM
battery modules can be connected in parallel. The
following is an example of connecting 3 modules to the charger.