Alliance Intelligent Battery Series
TM
User’s Guide
© 2020 American Battery Solutions Inc. All rights reserved. The data herein is intended as a guide and does not reflect the specification range for any particular property of this
product. Such data is based upon analysis of representative samples and not the actual product shipped. We based the information on data believed to be reliable on the date
compiled, but we do not represent, warrant, or otherwise guarantee, expressly or impliedly, the merchantability, fitness for a particular purpose, freedom from patent
infringement, suitability, accuracy, reliability, or completeness of this information or the products, materials or processes described.
Page 47
Operational Protection
Alarms and Settings
Table 14 lists the Alliance Intelligent Battery Series™ Operational Protection matrix
covering warnings, alarms and hardware circuitry for voltage and temperature.
Table 14: Alliance Intelligent Battery Series™
Operational Protection Settings
Warning Set
Value
ALLIANCE
INTELLIGENT
BATTERY
SERIES™
Moderate Set
Value
ALLIANCE
INTELLIGENT
BATTERY
SERIES™
Severe Set
Value
ALLIANCE
INTELLIGENT
BATTERY
SERIES™
Severe Clear
Condition
ALLIANCE
INTELLIGENT
BATTERY
SERIES™
Applies to
OVP Cell
4.101V
4.11V
4.15V
5s
Any cell
UVP Cell
2.99V
2.8V
2.75V
20s
Any cell
OTP Cell
50°C
55°C
65°C
2s
Battery
UTP Cell
2°C
0°C
-20°C
2s
Battery
OTP FET
N/A
N/A
80°C
1s
Battery
OCP HW
N/A
N/A
±250A
60s
Battery
Temperature
Imbalance
Protection
N/A
N/A
10°C/5°C (*)
1s
Battery
(Discharge/Charge)
Voltage
Imbalance
Protection
N/A
N/A
0.2V
10s
Battery
(*) Unique Discharge/Charge limits