b.
IGN-Based Wakeup
The Alliance Intelligent Battery Series™ can be woken by connecting the Ign Low
(Pin 2 of the low voltage connector) to the negative terminal of the battery or
connecting the Ign +12V to an external 12V source. (It is assumed that
connection to the negative terminal of the battery is through chassis ground or
the application wiring harness.) When either Ing pin is activated (Switching Ign
Low to ground or applying 12V to Ign +12V) will enter Drive mode (assuming no
failures are present), at which point Discharge and Charge functions are
available. The BMS will enter sleep mode within 5 seconds of removing the
Ignition signal.
Pins on the Alliance Intelligent Battery Series™ low voltage connector that are not
used should be left not connected (NC).
Figure 7: CAN Connector Pin-out
Battery Management System (BMS) Modes of
Operation
The Alliance Intelligent Battery Series™ has 5 Major states of Operation:
1.
Standby Not Ready (fault condition present)
2.
Standby
3.
Drive
4.
Charge
5.
Sleep