Error resolution and maintenance –
Identifying errors |
49
Error F9
Description
Flash pattern
Per cycle, the green battery icon flashes three
times on its own, followed by the green battery
icon and the blue power symbol flashing togeth-
er once.
The red warning symbol remains ON.
Cause
Suggested solution
The current monitoring module has detected that
the charging current is exceeding the preset max-
imum current.
The wallbox automatically reinitiates the charging proce-
dure every 60 seconds. If the error persists, the wallbox
and/or the vehicle must be checked: please contact a quali-
fied specialist electrical contractor or a specialist repairer.
Error F10
Description
Flash pattern
Per cycle, the green battery icon flashes twice on
its own, followed by the green battery icon and
the blue power symbol flashing together twice.
The red warning symbol remains ON.
Cause
Suggested solution
The temperature monitoring device has detect-
ed a temperature above 80° Celsius inside the
housing.
The temperature monitoring device interrupts the charging
procedure. After 10 minutes, the charging procedure is
reinitiated automatically. If the temperature inside the
housing remains at between 60° and 80° Celsius at this
time, error code
F17
(see below) is shown and the charging
current is limited to 6 A.
The charging procedure is re-initiated as soon as the tem-
perature inside the housing falls to below 60° Celsius.
If the error repeats or persists, the wallbox must be cooled
and/or shaded more effectively at the installation site.
Should the error persist, please take the wallbox out of
operation (see page 53) and contact a qualified specialist
electrical contractor to resolve the error.
Error F11
Description
Flash pattern
Per cycle, the green battery icon flashes once on
its own, followed by the green battery icon and
the blue power symbol flashing together three
times.
The red warning symbol remains ON.