RESOLVINg ERRORS
29
The indica-
tor LEDs
on the
RFID mod-
ule show
an error
sequence
The
eMC2
detects
a malfunction
via the back end
device
The
eMC2
reinitiates the charging process ev-
ery 30 seconds: Should the error persist, please
contact your service partner for the vehicle.
All errors indicated by the LEDs on the RFID mod-
ule relate to the RFID login procedure. Should
the error persist, re-register the RFID cards or
contact your local distributor.
Checking the internal RCCB
To ensure the continuing safe operation of the charging station, you must check the
function of the integrated residual current circuit breakers (RCCB) yourself every 6
months: Every RCCB has a button with which to initiate the test function.
Proceed as follows to test the RCCB:
1. Open the housing cover of the
eMC2
using the flip out handle.
2. Locate the RCCB: There is a button engraved
T
or marked
Test
.
3. Press the button: The RCCB should now trip and flick the pivot lever of the RCCB
into the
0
position (connection to the power supply is interrupted).
4. Switch the RCCB back on by flipping the pivot lever up into the
I
position and close
the cover of the
eMC2
.
DANGER!
Should the RCCB not trip during testing, there is a danger of malfunc-
tion: In this case you must under no circumstances continue to oper-
ate the charging pole!
Please contact your local distributor from whom you have purchased
the charging station.