INSTALLINg ThE ChARgINg pOLE
21
7. Fix the wires in the terminals using the hex key.
8. Ensure that all supply wires are properly tightened and are not under strain.
9. Insert the separately available NH fuses.
10. Replace the VBN cover.
11. Close the housing cover using the flat head screwdriver.
12. Switch on all internal safety switches and RCCBs inside the charging pole (
I ON-
position).
13. Close the pole cover and lock it using the flip out handle.
CAUTION!
It is recommended for operation that you install a cylinder lock in the flip
out handle of the charging pole to prevent any unauthorized opening of
the housing. Commercially available size 40 or 45 half profile cylinders
are suitable for this purpose.
PLEASE NOTE:
The
eMC445K
charging pole has an internal terminal block for connec-
tion to the electricity grid: The terminals are marked unequivocally and
the power supply can be screwed directly to the terminals using the
above table.
After the power supply has been connected inside the charging pole, the NH fuses for
the power supply can be put back by the power distribution network operator. Voltage
can then be applied to the charging pole by a qualified electrical contractor and it can
be taken into operation.