Operation Manual / TPL65VA10 / VA30
Disassembly and assembly
8
Installing cartridge group
8.9
Page 103
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2487_
EN
R
ev
is
ion
C
CAUTION
If there is no or insufficient clearance between the rotor turbine blades
and the turbine diffuser, the blades and the turbine diffuser (casing) can
be damaged.
Turn the rotor to check that the blades do not rub against the turbine
diffuser.
Remove the lifting gear.
Fit the O-ring (42012).
Screw in the speed sensor (86505) along with the O-ring (86506) and
plug in the cable connector (86515).
Fit the O-rings (77005 & 77006).
Fit the lifting gear and the swivel lifting eye (90230).
Align the wall insert (77000) to the threaded holes in the compressor
casing (72000) using the lugs on the swivel lifting eyes, then lower it.
Fit the diffuser (79000).
Tighten the screw (72002) as far as it will go and then back it off ¼
turn. Do not tighten the screw; the diffuser must be able to move.