Operation Manual / TPL65VA10 / VA30
Operation
4
Emergency operation TPL..VA
4.5
Page 50
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2487_
EN
R
ev
is
ion
C
Emergency operation TPL..VA
4.5
In the event of failure of the control system or the drive, the variable tur-
bine geometry module can be fixed by clamping the ring lever (B) using at
least 3 washers (C) spaced around the circumference.
When fixing, the position of the variable turbine geometry module and / or
the blades must be specified by the enginebuilder.
4.5
Detail A