Cleaning the filter silencer
5.2
Page 57
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2487_
EN
R
ev
is
ion
C
Unscrew and remove lock nuts (81273).
Unscrew and remove screws (81272) for connecting rods (81269).
Remove connecting rods (81269).
Carefully remove cover grids (81266).
Pull out insert units (E), bend open sheet-metal coverings (81137) and
then remove absorption segments (81136).
Clean the absorption segments (81136).
During cleaning, ensure that the absorption segments (81136) are only
cleaned with a mild jet of compressed air, soft brush or a damp cloth.
Otherwise there is a risk of damage or deformation.
NOTICE
Replace heavily contaminated or damaged parts with original parts from
ABB Turbo Systems.