Operation Manual / TPL65VA10 / VA30
Disposing of turbocharger components
11
Taking the engine out of operation for
more than 12 months
10.2
Page 121
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2487_
EN
R
ev
is
ion
C
Disposing of turbocharger components
WARNING
Handling damaged thermal insulation
Damaged thermal insulation can lead to dust exposure. The glass fibres
can cause mechanical irritation of the eyes, skin, and respiratory tracts.
Avoid the formation of dust.
Vacuum up dust with a suitable vacuum cleaner.
Wear a respiratory mask to protect against dusts (P1 or P2 mask).
Wear work gloves made of leather.
Wear safety goggles.
Wear a respiratory mask to protect against particles.
Wear safety gloves against mechanical risks.
Disposal must be environmentally compatible, professional, and in com-
pliance with locally applicable regulations.
The turbocharger consists largely of metal (cast iron materials, steel,
nickel-steel alloys, aluminium and bearing brass).
Further components are: Non-metallic materials (filter components of felt
and polyethylene), lubricants (engine oil), electronic parts (speed sensor
and associated components), and thermal insulation.
Dispose of metals as scrap metal for recycling.
Dispose of non-metallic materials as waste.
Dispose of residues of lubricants as waste oil.
Dispose of electronic components as electronic waste.
Dispose of thermal insulation as hazardous waste.
11