Operation Manual / TPL65VA10 / VA30
Taking out of operation at short notice
9
Fit cover plate
9.2
Page 113
© Copyright 2016 ABB. All rights reserved.
N
ov
em
ber
2016
H
ZT
L2487_
EN
R
ev
is
ion
C
Further measures and information for operation with a turbocharger with
cover plate on 4-stroke engines
4-stroke engine with one turbocharger
No further measures are necessary. The engine can be operated as a
naturally-aspirated engine according to the engine builder's instructions.
4-stroke engine with several turbochargers
No further measures are necessary on engines with separate air and ex-
haust gas receivers. The engine can be operated as a naturally-aspirated
engine according to the engine builder's instructions.
The air line must be closed off at the engine end because the undamaged
turbochargers build up a receiver pressure.
CAUTION
The engine can be operated according to the engine builder's instruc-
tions. Attention must always be paid to the speed of the undamaged
turbocharger. The speed limit n
Bmax
given on the rating plate must not
be exceeded.
Separate receivers
Common receiver