Run the RAPID program procedure
CyclicBrakeCheck
.
Note
Cyclic Brake Check
cannot be dynamically activated or deactivated. If it is
configured to be active, it is always active. That is, a constant supervision to
verify the brake check has been performed within the configured time interval.
Cyclic Brake Check configuration
Use the following procedure to configure Cyclic Brake Check:
Note/illustration
Action
In the
Visual SafeMove
tab ribbon, navig-
ate to the
Create
group, and click on the
Cyclic Brake Check
button.
The
Cyclic brake check properties
win-
dow is displayed.
1
WARNING
The
Warning only, no stop
check box
should not be selected under any circum-
stances.
Note
It is recommended to configure the maxim-
um value in
Max CBC test interval (h)
as 8
hours.
In
Max CBC test interval (h)
, set the
maximum allowed time (in hours) between
the cyclic brake checks.
2
In
Pre warning time (h)
, set how long
before the end of the interval a warning
should be displayed on the FlexPendant.
3
Continues on next page
182
Operating manual - OmniCore
3HAC065036-001 Revision: E
© Copyright 20192020 ABB. All rights reserved.
6 Programming and testing
6.10.8 Cyclic Brake Check service routine
Continued
Summary of Contents for OmniCore S Series
Page 1: ...ROBOTICS Operating manual OmniCore ...
Page 8: ...This page is intentionally left blank ...
Page 22: ...This page is intentionally left blank ...
Page 54: ...This page is intentionally left blank ...
Page 60: ...This page is intentionally left blank ...
Page 64: ...This page is intentionally left blank ...
Page 208: ...This page is intentionally left blank ...
Page 234: ......
Page 235: ......